Applied Concepts
Toll Free : 888.821.9766
Phone : 315.696.6676
Email :
Part Number: ACE-12-1275

CCFL Inverter - Single Lamp



Datasheet:
Input Cable:


Features
  • Power one CCFL, up to 15 watts output power capability
  • Provides self heating control, maintaining all specified safe operating limits, with smooth transition between temperature limits.
  • Lamp Outputs are Open and Short Circuit Protected
  • Wide range dimming capability, 500:1 typical
  • Average Electrical efficiency > 90%
  • Compact form factor
 
Specifications
  • Family: ACE
  • Number of Lamps:  1 lamp
  • 3.30”L x 1.00”W
  • Profile < 0.526”H
  • Weight:  27 grams
  • Enable control is accomplished at pin 3 of CON1 (0V = off, 5V = on)
  • Intensity Control (Vcntl):  0V off to 5V full on
  • Operating Temperature:   0 - 70°C
  • Safe operating area automatically maintained when display connector CN1 pins 31 and 32 are connected to Therm inputs of ACE (pins 7 and 8 of CON1).
  • Safe operating limits:  Temp < 25°C min duty cycle 9%, Temp > 50°C max duty cycle 80%
  • Input connector:  Molex 53261-0890
  • Output connector:  JST SM03(4.0)B-BHS-1-TB

This inverter is designed to drive the Sharp LQ058T5DR01.


Electrical Ratings Symbol Min Typ Max Unit
Input Voltage Vin 10.8 12 13.2 Vdc
Lamp Sustaining Voltage Lsv 700 850 1000 Vrms
Lamp Output Current Lout 8.8 mArms
Lamp Start Voltage Lstart 2400 Vrms